ELECTRIMOTION INC.
1484 DALE FORD RD.
DELAWARE, OH 43015
740.362.0251
ELECTRIC:
+12V input RED WIRE
GND BLACK WIRE
START GREEN WIRE
DELAYED OUTPUT BLUE WIRE
Output can source 4A @ 12V
OPERATION: When 12V is applied to the START input (Green Wire) the output will delay X sec. The output can be configured to be normally hi (12V) or normally low (0V)
8 PIN SWITCH
Add up the dip switch values to get the delay value.
Dip Sw on |
Time |
1 |
128 |
2 |
64 |
3 |
32 |
4 |
16 |
5 |
8 |
6 |
4 |
7 |
2 |
8 |
1 |
4 PIN SWITCH
Sw 1 Down Timer span is 0 – 2.56 sec in 0.01 sec increments
Sw 1 Up Timer span is 0 – 25.6 sec in 0.1 sec increments
Sw 2 Down Output is normally ON (12V), output switches OFF when timer elapses.
Sw 2 Up Output is normally OFF (0V), output switches ON when timer elapses.
Sw 3 Down Output will reset when the input is removed. Timer will start over.
Sw 3 Up Output will reset 15 sec after timer elapses.
Power must be cycled after making a
mode change .